Apr 01, 2020

Filter cartridge installation and cleaning method

Kite yon mesaj

The commonly used automatic cleaning methods of filter cartridges include high-pressure gas pulse back blowing and mechanical vibration. Pulse backflushing uses a preset parameter of the controller to give a signal to the solenoid valve, instantaneously open and close the solenoid valve diaphragm, so that high-pressure gas enters the blowing pipe, and use the rapid expansion of the gas to shake off the dust on the surface of the filter cartridge. We set it to about 6 kgf. Mechanical vibration dust removal is often used in small stand-alone filter drum dust collectors. It uses the shaking force generated by the eccentric device on the dust collector flower plate to remove dust. This action needs to be operated after shutdown.